Butler Group Test and Measurement General Yokogawa AQ6370 Series Optical Spectrum Analyser
Yokogawa AQ6370 Series Optical Spectrum Analyser
The world’s most trusted
OSAs
AQ6370 Series
Optical Spectrum Analyzer
The world’s most trustedOSAsAQ6370 SeriesOptical Spectrum Analyzer
Selection guide
The AQ6370 series are high-speed and high-performance Optical Spectrum Analyzers based on the diffraction
grating technology.
They satisfy measurement needs of a wide range of R&D and industrial manufacturing applications with a product
lineup of five models covering the broad wavelength range from visible light to mid-infrared (350 to 3400 nm).
AQ6370D Dedicated for telecom applications
Optical communications
• Wavelength range: 600 to 1700 nm
• Wavelength accuracy: ±0.01 nm (high-performance model)
• Wavelength resolution setting: 0.02 to 2 nm
• Level range: +20 to −90 dBm
• Close-in dynamic range:
78 dB typ. (peak ±1.0 nm, high-performance model)
<Applications>
• Emission spectrum evaluation of optical transceivers
and LD modules
• OSNR measurement of WDM transmission signals
• Optical amplifier (EDFA) measurement
AQ6373B Optimized for visible light measurements
VIS
• Wavelength range: 350 to 1200 nm
• Wavelength accuracy: ±0.05 nm
• Wavelength resolution setting: 0.01 to 10 nm
• Level range: +20 to −80 dBm
• Close-in dynamic range: 60 dB (peak ±0.5 nm)
<Applications>
• Characterization of light sources used in biomedical and
consumer products
• Color analysis of visible LED
AQ6375B Long wavelength model covering the exNIR region over 2 μm
exNIR
• Wavelength range: 1200 to 2400 nm
• Wavelength accuracy: ±0.05 nm
• Wavelength resolution setting: 0.05 to 2 nm
• Level range: +20 to −70 dBm
• Close-in dynamic range: 55 dB (peak ±0.8 nm)
<Applications>
• Characterization of sources used in Laser Absorption
Spectroscopy
• Characterization of broadband light sources such as
Supercontinuum light sources
• Measurement of gas absorption spectra
AQ6376 Long wavelength model covering the MWIR region over 3 μm
MWIR
• Wavelength range: 1500 to 3400 nm
• Wavelength accuracy: ±0.50 nm
• Wavelength resolution setting: 0.1 to 2 nm
• Level range: +13 to −65 dBm
• Close-in dynamic range: 55 dB (peak ±2.0 nm)
<Applications>
• Characterization of sources used in Laser Absorption
Spectroscopy
• Characterization of broadband light sources such as
Supercontinuum light sources
• Measurement of gas absorption spectra
AQ6374 Wide range model covering the spectrum from visible to
communication wavelengths
VIS & optical communications
• Wavelength range: 350 to 1750 nm
• Wavelength accuracy: ±0.05 nm
• Wavelength resolution setting: 0.05 to 10 nm
• Level range: +20 to −80 dBm
• Close-in dynamic range: 60 dB (peak ±1.0 nm)
<Applications>
• Wavelength loss characteristics of optical fibers
• Characterization of broadband light sources
• Characterization of lasers from visible light to optical
communications wavelengths
- More Info Available View...
- Calibration Available